TY - JOUR
T1 - Deceptive intensities
T2 - An exploratory strategy for overcoming early central fatigue in resistance training
AU - Gorzi, Ali
AU - Rezapour, Neda
AU - Jabbari, Sepideh
AU - Youzbashi, Leila
AU - Salehi, Javad
AU - Gahreman, Daniel
AU - Krause Neto, Walter
N1 - Funding Information:
Neda Rezapour has received a research grant from the University of Zanjan .
PY - 2022/10/15
Y1 - 2022/10/15
N2 - Neuropsychological stress induced by misleading information can limit human performance, possibly by early central fatigue mechanisms. In this study, we investigated the impact caused by prescribing misleading intensities of resistance exercise on acute electroencephalogram (EEG) and electromyogram (EMG) responses and the total number of repetitions to exhaustion. Collegiate female students performed three sets of biceps curls to exhaustion. The actual intensity for all sets was set at 65% 1-Repetition Maximum (1-RM). However, participants were deceptively informed that the intensities were 60%, 65%, or 70% 1-RM. The number of repetitions to fatigue and the magnitude of EEG and EMG signals were analyzed. The number of repetitions to exhaustion was significantly lower in greater announced intensities (18.11 ± 8.44) compared to lower (29.76 ± 16.28; p = 0.017) and correctly (27.82 ± 11.01; p = 0.001) announced intensity. The correlation between frontal and motor-cortex signals was significant in lower (r = 0.72, p = 0.001) and higher (r = 0.64, p = 0.005) announced intensities. The median and mean frequencies of EMG signal and Root Mean Square (RMS) did not show any significant difference between sets, but the peak-to-peak range (PPR) of biceps EMG signals was significantly higher in lower intensity (0.145 ± 0.042) when compared with higher (0.104 ± 0.044; p = 0.028) or correctly (0.126 ± 0.048; p = 0.037) announced intensity. It seems that deceptive information regarding the mass of an object could affect the number of repetitions to exhaustion and PPR to cover muscle capacity in endurance-type strength training.
AB - Neuropsychological stress induced by misleading information can limit human performance, possibly by early central fatigue mechanisms. In this study, we investigated the impact caused by prescribing misleading intensities of resistance exercise on acute electroencephalogram (EEG) and electromyogram (EMG) responses and the total number of repetitions to exhaustion. Collegiate female students performed three sets of biceps curls to exhaustion. The actual intensity for all sets was set at 65% 1-Repetition Maximum (1-RM). However, participants were deceptively informed that the intensities were 60%, 65%, or 70% 1-RM. The number of repetitions to fatigue and the magnitude of EEG and EMG signals were analyzed. The number of repetitions to exhaustion was significantly lower in greater announced intensities (18.11 ± 8.44) compared to lower (29.76 ± 16.28; p = 0.017) and correctly (27.82 ± 11.01; p = 0.001) announced intensity. The correlation between frontal and motor-cortex signals was significant in lower (r = 0.72, p = 0.001) and higher (r = 0.64, p = 0.005) announced intensities. The median and mean frequencies of EMG signal and Root Mean Square (RMS) did not show any significant difference between sets, but the peak-to-peak range (PPR) of biceps EMG signals was significantly higher in lower intensity (0.145 ± 0.042) when compared with higher (0.104 ± 0.044; p = 0.028) or correctly (0.126 ± 0.048; p = 0.037) announced intensity. It seems that deceptive information regarding the mass of an object could affect the number of repetitions to exhaustion and PPR to cover muscle capacity in endurance-type strength training.
KW - Early central fatigue
KW - Mental barriers
KW - Neuromuscular communication
KW - Performance
KW - Training Strategy
UR - http://www.scopus.com/inward/record.url?scp=85134929866&partnerID=8YFLogxK
U2 - 10.1016/j.physbeh.2022.113921
DO - 10.1016/j.physbeh.2022.113921
M3 - Article
AN - SCOPUS:85134929866
SN - 0031-9384
VL - 255
SP - 1
EP - 8
JO - Physiology and Behavior
JF - Physiology and Behavior
M1 - 113921
ER -