Abstract
Original language | French |
---|---|
Pages (from-to) | 61-68 |
Number of pages | 8 |
Journal | TSM Techniques Sciences Methodes |
Issue number | 1-2 |
Publication status | Published - 2010 |
Externally published | Yes |
Fingerprint
Cite this
}
Retour d'expérience sur l'utilisation de la turbidité en rivière de montagne. / Némery, J.; Mano, V.; Navrátil, O.; Gratiot, N.; Duvert, C.; Legout, C.; Belleudy, P.; Poirel, A.; Esteves, M.
In: TSM Techniques Sciences Methodes, No. 1-2, 2010, p. 61-68.Research output: Contribution to journal › Article › Research › peer-review
TY - JOUR
T1 - Retour d'expérience sur l'utilisation de la turbidité en rivière de montagne
AU - Némery, J.
AU - Mano, V.
AU - Navrátil, O.
AU - Gratiot, N.
AU - Duvert, C.
AU - Legout, C.
AU - Belleudy, P.
AU - Poirel, A.
AU - Esteves, M.
PY - 2010
Y1 - 2010
N2 - Turbidimeters are used by the scientific community and the rivers managers for the survey of sediment transport in mountainous watersheds. Many mountainous watersheds in the French Alps and in the volcanic highlands of Mexico were equipped with turbidimeters for the continuous survey of the Suspended Sediments Concentrations (SSC). In such watersheds, SSC concentrations reach extreme values (ten to hundred grams per litre). Two sensors of high range concentrations were tested and are used routinely. This paper deals with the feedback on the in situ instrumentation and on the building of SSC/turbidity calibration curve. It also shows the utility of this type of measurement for the calculation of sediments fluxes and particulate pollution fluxes in rivers.
AB - Turbidimeters are used by the scientific community and the rivers managers for the survey of sediment transport in mountainous watersheds. Many mountainous watersheds in the French Alps and in the volcanic highlands of Mexico were equipped with turbidimeters for the continuous survey of the Suspended Sediments Concentrations (SSC). In such watersheds, SSC concentrations reach extreme values (ten to hundred grams per litre). Two sensors of high range concentrations were tested and are used routinely. This paper deals with the feedback on the in situ instrumentation and on the building of SSC/turbidity calibration curve. It also shows the utility of this type of measurement for the calculation of sediments fluxes and particulate pollution fluxes in rivers.
KW - Calibration curves
KW - Extreme value
KW - French Alps
KW - In-situ
KW - Me-xico
KW - Mountainous rivers
KW - Particulate pollution
KW - Scientific community
KW - Suspended sediments concentration, Landforms
KW - Sediment transport
KW - Sedimentology
KW - Surveys
KW - Turbidity
KW - Watersheds, Rivers, calibration
KW - mountain region
KW - sediment transport
KW - turbidity
KW - upland region
KW - watershed, Alps
KW - France
KW - Mexico [North America]
M3 - Article
SP - 61
EP - 68
JO - TSM Techniques Sciences Methodes
JF - TSM Techniques Sciences Methodes
SN - 2260-958X
IS - 1-2
ER -